Detail GC1290 Gas Chromatography (LCD Touch Screen) Brand Drawell
Alat Laboratorium Analisis Makanan
Application of GC1290 Gas Chromatography:
GC1290 gas chromatography is a chromatographic analysis method with gas as the mobile phase, which is mainly used for the separation and analysis of volatile substances. Gas chromatography has become one of the most important separations and analysis methods, and has been widely used in the fields of medicine and health, petrochemical industry, environmental monitoring, biochemistry, and so on.
Features of the Gas Chromatography:
Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”).
Advanced built-in data acquisition system, supporting real-time instrument status monitoring, detection signal acquisition, and PC control.
Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with the automated back-door opening. (400℃ to 50℃ in 6 min at 25℃ ambient).
Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures).
Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards.
Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ FPD/ NPD
Specifications of the Split Beam UV/VIS Spectrophotometer
Model
DW-GC1290
Description
EPC(electronic pneumatic control) 7 inch touch screen display
Sample Introduction System
sample injector and evaporation chamber
Column Oven
Temperature range
Ambient temperature +7℃ ~ 400℃ (in 1℃incremen
Temperature accuracy
± 0.02℃
Cooling time
350℃〜100℃≤3min,
400℃ to 50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1℃~40℃/min (in 1℃ increment)
Program ramps
20 ramps in total (10 ramps available with
control workstation
Size (L*W*H)
284*280*241mm(inside)340*345*281mm(outside)
Flame Ionization
Detection limit
≤8×10- 12 g/s (n-hexadecane)
Detector (FID)
Thermal Conductivity Detector(TCD)
Drift
≤1.5×10- 13 A/h
Noise
≤3×10- 14 A
Linearity range
≥106
Flame Photometric Detector(FPD)
Detection limit
≤8×10- 13 g/s(P) ; ≤8×10- 11 g/s(S)
Drift
≤2×10- 11 A/30min
Baseline noise
≤5×10- 12 A
Nitrogen-Phosphorus Detector(NPD)
Detection limit
≤5×10- 13 g/s(P) ( Malathion);
≤5×10- 12 g/s(N)( Azobenzene)