Detail Ecotech Serinus 30 Carbon Monoxide Analyzer
Detail Ecotech Serinus 30 Carbon Monoxide Analyzer
SERINUS 30
CARBON MONOXIDE
ANALYSER
The Serinus 30 carbon monoxide (CO) analyser delivers
precise and reliable performance at excellent value. It uses
proven NDIR gas filter correlation technology to measure
CO in ambient air (LDL <40 ppb, range 0 - 200 ppm).
Benefits include:
• Reliable performance complemented with a two
year warranty.
• Minimises time spent on site performing
maintenance through superior remote instrument
control, diagnostic viewing and calibration.
• Comprehensive data logging and remote viewing of
over 200 operational parameters.
• Versatile interfacing through RS232, USB, Bluetooth,
analog and digital I/O and optional TCP/IP.
• Easy setup through an intuitive menu system,
advanced GUI and a large alphanumeric keypad
with tactile keys.
• Instant status indication via illuminated instrumenstatus light buttons on the front panel.
• Removable flash memory stores ~10 years of data,
including up to 12 individual parameters and event
logs. Operational parameters can also be transferred
to memory for easy retrieval.
• Latest firmware updates can easily be installed using
the USB flash memory drive.
• Programming, viewing, doof data is made even simpler using Bluetconnectivity combined with the
Remote” Android App.
• Built-in digital display measuring values and having
function of measuring values transferred to graphical
trend display.
• Enhanced operator safety through the use of 12 VDC
internal voltages.
• Reduced cost of spare parts, accessories and
consumable items through extensive use of standard
components across the Serinus range.
• Rack slide design makes accessing internal
components and removing the analyser from a rack
cabinet easy.
• AQMS power usage can be reduced due to the
instrument’s low power demand and its ability toperate over a wide temperature range.
APPROVALS
• US EPA approval (RFCA–0509–174)
• EN approval TÜV (936/21221977/D)
• EN approval MCERTS (MC100166/06)
• Australian Standard (AS 3580.7.1-2011)
• Russian approval (56262-14)
SPECIFICATIONS
Range: 0 - 200 ppm (autoranging)
Concentration units: mg/m3, ug/m3, ng/m3, ppb, ppb, or ppt.
Noise: < 0.02 ppm or 0.2 % of
concentration reading
whichever is greater
Lower detectable limit: < 0.04 ppm or 0.2 % of reading
whichever is greater
Linearity: < 1 % of full scale (0-50 ppm)
Precision: 0.1 ppm or 0.1 % of reading
whichever is greater
Zero drift (24 hours): < 0.1 ppm
Zero drift (7 days): < 0.1 ppm
Span drift (7 days): < 0.5 % of reading
Response time: 60 seconds to 95 %
STP reference: 0 °C, 20 °C, 25 °C at 101.3 kPa
Sample flow rate: 1000 cc/min
Temperature range: 0 - 40 °C
Operating power: 100 - 240 VAC, 50 - 60 Hz
(autoranging)
Power consumption: 260 VA (max at start-up)
150 VA (nominal)
Dimensions: (W) 429 x (H) 175 x (D) 638 mm
Rack spacing: 3.5 RU
Weight: 17.8 kg
Communication:
• #1 RS232 port (supports all protocols*)
• #2 RS232 port (supports all protocols* and multidrop)
• USB port (Advanced protocol only)
• Bluetooth (Advanced protocol only)
• TCP/IP network port (optional, supports all protocols*)
Data logging:
8 GB removable USB flash memory drive that scores
the internal data logger, event log, automatic/manual
configuration backup, automatic/manual parameter list
save.
• Internal data logger (can log up to 12 of 200+parameters)
• Logger interval (1 second to 24 hours)
• Storage capacity ~ 10 years (set to 1 minute interval)