Back to Top

1
Hi, Guest!
  • Bante904 Benchtop Conductivity/Dissolved Oxygen Meter
Bante904 Benchtop Conductivity/Dissolved Oxygen Meter

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter

Update Terakhir 19 / 11 / 2021
Minimal Pembelian 1 Unit

Harga

CALL
Bagikan
DESKRIPSI PRODUK

Detail Bante904 Benchtop Conductivity/Dissolved Oxygen Meter

Alat Laboratorium Air
Bante904 Benchtop Conductivity/Dissolved Oxygen Meter
High-accuracy multiparameter water quality meter contains 13 options, the meter is suitable for measuring the conductivity, TDS, salinity, resistivity and dissolved oxygen.

Conductivity/TDS/Salinity/Resistivity Modes:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement erro
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.
SpecificationsOrdering InfoOptional AccessoriesPackaging
Model


Bante904
Conductivity




Range


0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution


0.001, 0.01, 0.1, 1
Accuracy


±0.5% F.S.
Calibration Points


1 to 5 points
Calibration Solutions


10µS, 84µS, 1413µS, 12.88mS, 111.8mS
Temperature Coefficient


Linear (0.0 to 10.0%/°C), pure water
Reference Temperature


20/25°C
Cell Constant


K=0.1, 1, 10 or custom
TDS




Range


0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution


0.01, 0.1, 1
Accuracy

±1% F.S.
TDS Factor

0.1 to 1.0 (default 0.5)
Salinity




Range


0.00 to 80.00ppt, 0.00 to 42.00psu
Resolution


0.01
Accuracy

±1% F.S.
Resistivity




Range


0.00 to 20.00MΩ
Resolution


0.01
Accuracy


±1% F.S.
Dissolved Oxygen




DO Range


0.00 to 20.00mg/L
Resolution


0.01, 0.1mg/L, selectable
Accuracy


±0.2mg/L
% Saturation of Oxygen


0.0 to 200.0%
Resolution


0.1, 1%, selectable
Accuracy


±2.0%
Calibration Points


1 or 2 points
Pressure Correction


60.0 to 112.5kPa/450 to 850mmHg, manual
Salinity Correction


0.0 to 50.0g/L, manual
Temperature




Range


0 to 105°C/32 to 221°F
Resolution


0.1°C/0.1°F
Accuracy


±0.5°C/±0.9°F
Offset Calibration


1 point
Calibration Range


Reading ±10°C
General Specifications




Temperature Compensation


0 to 100°C/32 to 212°F, manual or automatic
Stability Criteria

Low or high
Calibration Due Alarm


1 to 31 days or off
Memory

Stores up to 500 data sets
Output

USB communication interface
Connector

6-pin nimi-DIN, 3.5mm jack socket
Display

Custom LCD (125×100mm)
Power

DC5V, using AC adapter, 220V/50Hz
Dimensions


210(L)×188(W)×60(H)mm
Weight


1.5kg