Back to Top

1
Hi, Guest!
  • Bante903P Portable pH/DO Meter
Bante903P Portable pH/DO Meter

Bante903P Portable pH/DO Meter

Update Terakhir 20 / 11 / 2021
Minimal Pembelian 1 Unit

Harga

CALL
Bagikan
DESKRIPSI PRODUK

Detail Bante903P Portable PH/DO Meter

PH Meter
Bante903P Portable pH/DO Meter
Multiparameter portable pH/DO meter contains 3 measurement modes, the meter is suitable for measuring the pH, ORP and dissolved oxygen.

pH Mode:
• Multiparameter portable pH/DO meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement error.
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Auto-Power Off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to PC.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the
meter smoothly.
SpecificationsOrdering InfoOptional AccessoriesPackaging
Model


Bante903P
pH




Range


-2.000 to 20.000pH
Resolution


0.001, 0.01, 0.1pH, selectable
Accuracy


±0.002pH
Calibration Points


1 to 5 points
pH Buffer Options


USA, NIST, DIN, 2 custom buffers
ORP




Range


±1999.9mV
Resolution


0.1, 1mV, selectable
Accuracy


±0.2mV
Calibration Points


1 point
Measurement Modes


Relative or absolute mV
Dissolved Oxygen




DO Range


0.00 to 20.00mg/L
Resolution


0.01, 0.1mg/L, selectable
Accuracy


±0.2mg/L
% Saturation of Oxygen


0.0 to 200.0%
Resolution


0.1, 1%, selectable
Accuracy


±2.0%
Calibration Points


1 or 2 points
Pressure Correction


60.0 to 112.5kPa/450 to 850mmHg, manual
Salinity Correction


0.0 to 50.0g/L, manual
Temperature




Range


0 to 105°C/32 to 221°F
Resolution


0.1°C/0.1°F
Accuracy


±0.5°C/±0.9°F
Offset Calibration


1 point
Calibration Range


Reading ±10°C